Foto Diaphragm Pressure Gauge BDT12

Badotherm Diaphragm Pressure Gauge BDT12

Pengukur tekanan Badotherm model BDT12 adalah pengukur tekanan tipe diafragma
dan cocok untuk semua media gas dan cair, serta untuk media kental dan
padatan tersuspensi. Pengukur tekanan ini biasanya digunakan untuk aplikasi dalam
kimia, petro-kimia, minyak & gas, listrik dan utilitas, pembuatan mesin dan
industri proses umum. Pengukur ini dapat dibuat dengan koneksi bergelang sesuai standar ANSI, DIN, dan JIS.

Rp0,00

Kategori: Tag:

Deskripsi

Spesifikasi Badotherm Diaphragm Pressure Gauge BDT12 :

  • Merk : Badotherm
  • Model : BDT12

Design Information :

  • Design Norm : EN 837-3
  • Ingress Protection : IP65 per IEC 60529

Standard Model Material Specifications :

  • Process Connection : AISI316(L)
  • Diaphragm : AISI316(L) / Duratherm
  • Case : AISI304, bayonet
  • Bezel : AISI304, bayonet
  • Movement : Stainless Steel
  • Window : Glass
  • Pointer : Aluminium, black
  • Dial : Aluminium, white with black markings

Technical Specifications :

  • Diameter : 100 / 160 mm
  • Connection : 1/2″ BSP/NPT
  • Minimum range : 600 mbar
  • Maximum range : 25 bar
  • Accuracy : 1.6% FSD
  • Pointer : Adjustable slotted
  • Mounting variations : A
  • Diaphragm :AISI316 / Duratherm
  • Connection construction : Welded
  • Blow out : on the back
  • Compensation plug, material : NBR
  • Window gasket : NBR

Special Executions :

  • BDT12-S : With AISI316(L) case and bezel
  • BDT12-09 : With sanitary connection

Options :

  • Window : Laminated safety glass or plastic
  • Process Connection : Other
  • Pointer : Red pointer on dial, or drag pointer
  • Wetter Parts : PTFE lining
  • Protection Sheet : PTFE foil, Monel 400, Hastelloy C-276, or Tantalum (vacuum up to -50 mbar)
  • Filling : BPF01 (glycerine), BPF02 (silicon), BPF03 (for contacts), BPF04 (foaming service), BPF05 (ECTFE Inert for oxygen service)
  • Cleaning : Oxygen service (in case of filling use BPF05)
  • Calibration Certificates : 5 points (rising and falling)
  • ATEX : EX II 2 GD c (ATEX 94/9/EC)
  • Accessories : Please check for matching accessories such as siphons (BDT42), snubbers (BDT45), swivel gauges (BDT47), overpressure protectors (BDT49), diaphragm seals and instrument needle valves and manifolds

Datasheet