Description
Spesifikasi LSW Vortex Flow Meter LSW-SM-VM
Brand : LSW
Model : LSW-SM-VM
- Application Range : (1) Gas; (2) Liquid; (3) Steam
- Measured Value :
- Primary Measured Value : Flow Rate
- Secondary Measured Value : Volume flow (Pressure and Temperature is available)
- Temperature :
- Process Temperature :
T1 Level: -20℃…+100℃
T2 Level: -20℃…+250℃
T3 Level: -20℃…+350℃
T4 Level: -20℃…+420℃
- Process Temperature :
- Ambient Temperature : -10℃…+50℃
- Pressure :
- EN 1092-1 :
DN200…DN300: PN10
DN100…DN200: PN16
DN15…DN80: PN25
Other pressure in request - ASME B 16.5 :
1/2”…8”: 150 Ib RF
Other pressure in request - JIS :
1/2”…8”: 10K
Other pressure in request - Reference Condition :
Flow conditions similar to EN 29104
Medium: Water/Gas/Steam
Temperature: -10℃…+30℃
Inlet Section: ≥10DN
- EN 1092-1 :
- Accuracy :
For Liquid: ±1.0% of rate
For Steam and Gas:±1.5% of rate - Body Material :
SS304
SS306 - Converter Material : Standard: Polyurethane coated die-cast aluminum
Reviews
There are no reviews yet.