Schneider Contactor LC1D09B7 1

Schneider Contactor LC1D09B7

Jual Schneider Electric Contactor

3P(3 NO) – AC-3 – <= 440 V 9 A – 24 V AC coil

 

Rp0,00

Deskripsi

Spesifikasi Schneider Contactor LC1D09B7

  • Merk : Schneider Electric
  • Model / Part Number : LC1D09B7
  • Series : TeSys D

Main

  • Short name : LC1D
  • Contactor application :
    Motor control
    Resistive load
  • Utilisation category :
    AC-3
    AC-1
    AC-4
  • Poles description : 3P
  • Power pole : 3 NO
  • [Ue] rated operational voltage :
    <= 300 V DC for power circuit
    <= 690 V AC 25…400 Hz for power circuit
  • [Ie] rated operational current :
    25 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit
    9 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit
  • Motor power kW :
    2.2 kW at 400 V AC 50/60 Hz AC-4
    2.2 kW at 220…230 V AC 50/60 Hz AC-3
    4 kW at 380…400 V AC 50/60 Hz AC-3
    5.5 kW at 500 V AC 50/60 Hz AC-3
    5.5 kW at 660…690 V AC 50/60 Hz AC-3
    4 kW at 415…440 V AC 50/60 Hz AC-3
  • Motor power HP (UL / CSA) :
    0.33 hp at 115 V AC 50/60 Hz for 1 phase motors
    1 hp at 230/240 V AC 50/60 Hz for 1 phase motors
    2 hp at 200/208 V AC 50/60 Hz for 3 phases motors
    2 hp at 230/240 V AC 50/60 Hz for 3 phases motors
    5 hp at 460/480 V AC 50/60 Hz for 3 phases motors
    7.5 hp at 575/600 V AC 50/60 Hz for 3 phases motors
  • Control circuit type : AC 50/60 Hz
  • [Uc] control circuit voltage : 24 V AC 50/60 Hz
  • Auxiliary contact composition : 1 NO + 1 NC
  • [Uimp] rated impulse withstand voltage : 6 kV conforming to IEC 60947
  • Overvoltage category : III
  • [Ith] conventional free air thermal current :
    25 A at <= 60 °C for power circuit
    10 A at <= 60 °C for signalling circuit
  • Irms rated making capacity :
    250 A at 440 V for power circuit conforming to IEC 60947
    140 A AC for signalling circuit conforming to IEC 60947-5-1
    250 A DC for signalling circuit conforming to IEC 60947-5-1
  • Rated breaking capacity : 250 A at 440 V for power circuit conforming to IEC 60947
  • [Icw] rated short-time withstand current :
    105 A <= 40 °C 10 s power circuit
    210 A <= 40 °C 1 s power circuit
    30 A <= 40 °C 10 min power circuit
    61 A <= 40 °C 1 min power circuit
    100 A 1 s signalling circuit
    120 A 500 ms signalling circuit
    140 A 100 ms signalling circuit
  • Associated fuse rating :
    20 A gG at <= 690 V coordination type 2 for power circuit
    25 A gG at <= 690 V coordination type 1 for power circuit
    10 A gG for signalling circuit conforming to IEC 60947-5-1
  • Average impedance : 2.5 mOhm at 50 Hz – Ith 25 A for power circuit
  • [Ui] rated insulation voltage :
    600 V for power circuit certifications CSA
    600 V for power circuit certifications UL
    690 V for power circuit conforming to IEC 60947-4-1
    690 V for signalling circuit conforming to IEC 60947-1
    600 V for signalling circuit certifications CSA
    600 V for signalling circuit certifications UL
  • Electrical durability :
    0.6 Mcycles 25 A AC-1 at Ue <= 440 V
    2 Mcycles 9 A AC-3 at Ue <= 440 V
  • Power dissipation per pole :
    0.2 W AC-3
    1.56 W AC-1
  • Safety cover : With
  • Mounting support :
    Plate
    Rail
  • Standards :
    CSA C22.2 No 14
    EN 60947-4-1
    EN 60947-5-1
    IEC 60947-4-1
    IEC 60947-5-1
    UL 508
  • Product certifications :
    LROS (Lloyds register of shipping)
    UL
    GOST
    RINA
    DNV
    GL
    CSA
    CCC
    BV
  • Connections – terminals :
    Control circuit : screw clamp terminals 2 cable(s) 1…2.5 mm² – cable stiffness: flexible – with cable end
    Power circuit : screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: flexible – with cable end
    Control circuit : screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: flexible – without cable end
    Control circuit : screw clamp terminals 2 cable(s) 1…4 mm² – cable stiffness: flexible – without cable end
    Control circuit : screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: flexible – with cable end
    Control circuit : screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: solid – without cable end
    Control circuit : screw clamp terminals 2 cable(s) 1…4 mm² – cable stiffness: solid – without cable end
    Power circuit : screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: flexible – without cable end
    Power circuit : screw clamp terminals 2 cable(s) 1…4 mm² – cable stiffness: flexible – without cable end
    Power circuit : screw clamp terminals 2 cable(s) 1…2.5 mm² – cable stiffness: flexible – with cable end
    Power circuit : screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: solid – without cable end
    Power circuit : screw clamp terminals 2 cable(s) 1…4 mm² – cable stiffness: solid – without cable end
  • Tightening torque :
    Power circuit : 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
    Power circuit : 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
    Control circuit : 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
    Control circuit : 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
  • Operating time :
    4…19 ms opening
    12…22 ms closing
  • Safety reliability level :
    B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
    B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
  • Mechanical durability : 15 Mcycles
  • Operating rate : 3600 cyc/h at <= 60 °C

Complementary

  • Coil technology : Without built-in suppressor module
  • Control circuit voltage limits :
    0.3…0.6 Uc drop-out at 60 °C, AC 50/60 Hz
    0.8…1.1 Uc operational at 60 °C, AC 50 Hz
    0.85…1.1 Uc operational at 60 °C, AC 60 Hz
  • Inrush power in VA :
    70 VA at 20 °C (cos ϕ 0.75) 60 Hz
    70 VA at 20 °C (cos ϕ 0.75) 50 Hz
  • Hold-in power consumption in VA :
    7.5 VA at 20 °C (cos ϕ 0.3) 60 Hz
    7 VA at 20 °C (cos ϕ 0.3) 50 Hz
  • Heat dissipation : 2…3 W at 50/60 Hz
  • Auxiliary contacts type :
    Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1
    Type mirror contact (1 NC) conforming to IEC 60947-4-1
  • Signalling circuit frequency : 25…400 Hz
  • Minimum switching current : 5 mA for signalling circuit
  • Minimum switching voltage : 17 V for signalling circuit
  • Non-overlap time :
    1.5 ms on energisation between NC and NO contact
    1.5 ms on de-energisation between NC and NO contact
  • Insulation resistance : > 10 MOhm for signalling circuit

Environment

  • IP degree of protection : IP20 front face conforming to IEC 60529
  • Protective treatment : TH conforming to IEC 60068-2-30
  • Pollution degree : 3
  • Ambient air temperature for operation : -5…60 °C
  • Ambient air temperature for storage : -60…80 °C
  • Permissible ambient air temperature around the device : -40…70 °C at Uc
  • Operating altitude : 3000 m without derating
  • Fire resistance : 850 °C conforming to IEC 60695-2-1
  • Flame retardance : V1 conforming to UL 94
  • Mechanical robustness :
    Vibrations contactor open 2 Gn, 5…300 Hz
    Vibrations contactor closed 4 Gn, 5…300 Hz
    Shocks contactor open 10 Gn for 11 ms
    Shocks contactor closed 15 Gn for 11 ms

Informasi Tambahan

Berat320 g
Dimensi86 × 45 × 77 mm

Datasheet

Ulasan

Belum ada ulasan.

Hanya pelanggan yang sudah login dan telah membeli produk ini yang dapat memberikan ulasan.