Spesifikasi Schneider Contactor LC1D65AD7 TeSys D
- Merk : Schneider Electric
- Model / Part Number : LC1D65AD7
- Series : TeSys D
Main
- Range : TeSys
- Product name : TeSys D
- Device short name : LC1D
- Contactor application :
Motor control
Resistive load - Utilisation category :
AC-3
AC-1
AC-4 - Poles : 3P
- Power pole contact composition : 3 NO
- [Ue] rated operational voltage :
<= 300 V DC for power circuit
<= 690 V AC 25…400 Hz for power circuit - [Ie] rated operational current :
80 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit
65 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit - Motor power kW :
11 kW at 400 V AC 50/60 Hz AC-4
30 kW at 380…400 V AC 50/60 Hz AC-3
37 kW at 500 V AC 50/60 Hz AC-3
37 kW at 660…690 V AC 50/60 Hz AC-3
18.5 kW at 220…230 V AC 50/60 Hz AC-3 - Motor power HP (UL / CSA) :
40 hp at 460/480 V AC 50/60 Hz for 3 phases motors
5 hp at 115 V AC 50/60 Hz for 1 phase motors
10 hp at 230/240 V AC 50/60 Hz for 1 phase motors
20 hp at 200/208 V AC 50/60 Hz for 3 phases motors
20 hp at 230/240 V AC 50/60 Hz for 3 phases motors
50 hp at 575/600 V AC 50/60 Hz for 3 phases motors - Control circuit type : AC 50/60 Hz
- [Uc] control circuit voltage : 220 V AC 50/60 Hz
- Auxiliary contact composition : 1 NO + 1 NC
- [Uimp] rated impulse withstand voltage : Conforming to IEC 60947
- Overvoltage category : III
- [Ith] conventional free air thermal current :
80 A at <= 60 °C for power circuit
10 A at <= 60 °C for signalling circuit - Irms rated making capacity :
1000 A at 440 V for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1 - Rated breaking capacity :
1000 A at 440 V for power circuit conforming to IEC 60947 - [Icw] rated short-time withstand current :
100 A 1 s signalling circuit
120 A 500 ms signalling circuit
140 A 100 ms signalling circuit
520 A <= 40 °C 10 s power circuit
900 A <= 40 °C 1 s power circuit
110 A <= 40 °C 10 min power circuit
260 A <= 40 °C 1 min power circuit - Associated fuse rating :
125 A gG at <= 690 V coordination type 1 for power circuit
125 A gG at <= 690 V coordination type 2 for power circuit
10 A gG for signalling circuit conforming to IEC 60947-5-1 - Average impedance : 1.5 mOhm at 50 Hz – Ith 80 A for power circuit
- [Ui] rated insulation voltage :
600 V for power circuit certifications CSA
600 V for power circuit certifications UL
690 V for power circuit conforming to IEC 60947-4-1
690 V for signalling circuit conforming to IEC 60947-1
600 V for signalling circuit certifications CSA
600 V for signalling circuit certifications UL - Electrical durability :
1.45 Mcycles 65 A AC-3 at Ue <= 440 V
1.4 Mcycles 80 A AC-1 at Ue <= 440 V - Power dissipation per pole :
6.3 W AC-3
9.6 W AC-1 - Safety cover : With
- Mounting support :
Plate
Rail - Standards :
CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508 - Product certifications :
CSA
CCC
GOST
UL - Connections – terminals :
Control circuit : screw clamp terminals 2 cable(s) 1…2.5 mm² – cable stiffness: flexible – with cable end
Power circuit : EverLink BTR screw connectors 1 cable(s) 1…35 mm² – cable stiffness: flexible – without cable end
Power circuit : EverLink BTR screw connectors 1 cable(s) 1…35 mm² – cable stiffness: flexible – with cable end
Power circuit : EverLink BTR screw connectors 1 cable(s) 1…35 mm² – cable stiffness: solid – without cable end
Power circuit : EverLink BTR screw connectors 2 cable(s) 1…25 mm² – cable stiffness: flexible – without cable end
Power circuit : EverLink BTR screw connectors 2 cable(s) 1…25 mm² – cable stiffness: flexible – with cable end
Power circuit : EverLink BTR screw connectors 2 cable(s) 1…25 mm² – cable stiffness: solid – without cable end
Control circuit : screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: flexible – without cable end
Control circuit : screw clamp terminals 2 cable(s) 1…4 mm² – cable stiffness: flexible – without cable end
Control circuit : screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: flexible – with cable end
Control circuit : screw clamp terminals 1 cable(s) 1…4 mm² – cable stiffness: solid – without cable end
Control circuit : screw clamp terminals 2 cable(s) 1…4 mm² – cable stiffness: solid – without cable end - Tightening torque :
Control circuit : 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit : 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
Power circuit : 8 N.m – on EverLink BTR screw connectors – cable 25…35 mm² hexagonal 4 mm
Power circuit : 5 N.m – on EverLink BTR screw connectors – cable 1…25 mm² hexagonal 4 mm - Operating time :
12…26 ms closing
4…19 ms opening - Safety reliability level :
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 - Mechanical durability : 6 Mcycles
- Operating rate : 3600 cyc/h at <= 60 °C
Complementary
- Coil technology : Without built-in suppressor module
- Control circuit voltage limits :
0.3…0.6 Uc drop-out at 60 °C, AC 50/60 Hz
0.8…1.1 Uc operational at 60 °C, AC 50 Hz
0.85…1.1 Uc operational at 60 °C, AC 60 Hz - Inrush power in VA :
140 VA at 20 °C (cos ϕ 0.75) 60 Hz
160 VA at 20 °C (cos ϕ 0.75) 50 Hz - Hold-in power consumption in VA :
13 VA at 20 °C (cos ϕ 0.3) 60 Hz
15 VA at 20 °C (cos ϕ 0.3) 50 Hz - Heat dissipation : 4…5 W at 50/60 Hz
- Auxiliary contacts type :
Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1
Type mirror contact (1 NC) conforming to IEC 60947-4-1 - Signalling circuit frequency : 25…400 Hz
- Minimum switching current : 5 mA for signalling circuit
- Minimum switching voltage : 17 V for signalling circuit
- Non-overlap time :
1.5 ms on de-energisation (between NC and NO contact)
1.5 ms on energisation (between NC and NO contact) - Insulation resistance : > 10 MOhm for signalling circuit
Environment
- IP degree of protection : IP20 front face conforming to IEC 60529
- Protective treatment : TH conforming to IEC 60068-2-30
- Pollution degree : 3
- Ambient air temperature for operation : -5…60 °C
- Ambient air temperature for storage : -60…80 °C
- Permissible ambient air temperature around the device : -40…70 °C at Uc
- Operating altitude : 3000 m without derating
- Fire resistance : 850 °C conforming to IEC 60695-2-1
- Flame retardance : V1 conforming to UL 94
- Mechanical robustness :
Vibrations contactor open 2 Gn, 5…300 Hz
Vibrations contactor closed 4 Gn, 5…300 Hz
Shocks contactor open 10 Gn for 11 ms
Shocks contactor closed 15 Gn for 11 ms