Description
Spesifikasi Schneider Magnetic Contactor LC1D25M7
- Merk : Schneider Electric
- Model / Part Number : LP1K0910BD
- Series : TeSys K
Main
- Range of product : TeSys K
- Range : TeSys
- Product or component type : Contactor
- Device short name : LP1K
- Contactor application :
Motor control
Resistive load - Utilisation category :
AC-3
AC-1
AC-4 - Poles description : 3P
- Pole contact composition : 3 NO
- [Ie] Rated operational current :
20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit
9 A at <= 440 V AC AC-3 for power circuit
16 A (at <70 °C) at 690 V AC AC-1 for power circuit - Auxiliary contact composition : 1 NO
Complementary
- Auxiliary contacts type : type instantaneous 1 NO
- Control circuit voltage limits :
Operational: 0.8…1.15 Uc (at <50 °C)
Drop-out: 0.1…0.75 Uc (at <50 °C) - [Ui] Rated insulation voltage :
Power circuit: 600 V conforming to UL 508
Power circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-5-1
Signalling circuit: 600 V conforming to UL 508
Power circuit: 600 V conforming to CSA C22.2 No 14
Signalling circuit: 600 V conforming to CSA C22.2 No 14 - [Uimp] Rated impulse withstand voltage : 8 kV
- Overvoltage category : III
- Mounting support :
Rail
Plate - Flame retardance :
V1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102 - Tightening torque :
1.3 N.m – on screw clamp terminals – with screwdriver Philips No 2
1.3 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm - [Ue] Rated operational voltage :
Power circuit: 690 V AC 50/60 Hz
Signalling circuit: <= 690 V AC 50/60 Hz - [Ith] Conventional free air thermal current :
20 A (at 50 °C) for power circuit
10 A (at 50 °C) for signalling circuit - Irms rated making capacity :
110 A AC for power circuit conforming to NF C 63-110
110 A AC for power circuit conforming to IEC 60947
110 A AC for signalling circuit conforming to IEC 60947 - Rated breaking capacity :
110 A at 415 V conforming to IEC 60947
110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
110 A at 220…230 V conforming to IEC 60947
110 A at 380…400 V conforming to IEC 60947
70 A at 660…690 V conforming to IEC 60947 - Associated fuse rating :
25 A gG at <= 440 V for power circuit
25 A aM for power circuit
10 A gG for signalling circuit conforming to IEC 60947
10 A gG for signalling circuit conforming to VDE 0660 - Average impedance : 3 mOhm – Ith 20 A 50 Hz for power circuit
- Inrush power in W : 3 W (at 20 °C)
- Hold-in power consumption in W : 3 W at 20 °C
- Operating time :
30…40 ms coil energisation and NO closing
10 ms coil de-energisation and NO opening - Safety reliability level :
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 - Mechanical durability : 10 Mcycles
- Maximum operating rate : 3600 cyc/h
- Minimum switching current : 5 mA for signalling circuit
- Minimum switching voltage : 17 V for signalling circuit
- Insulation resistance : > 10 MOhm for signalling circuit
Environment
- Product certifications :
UL
CSA - Ambient air temperature for operation : -25…50 °C
- Ambient air temperature for storage : -50…80 °C
- Operating altitude : 2000 m without