Deskripsi
Spesifikasi Schneider MCCB (Molded Case Circuit Breakers) LV429541
- Merk : Schneider Electric
- Model / Part Number : LV429541
Main
- Range: Compact
- Product name: Compact NSX
- Product or component type: Circuit breaker
- Device short name: Compact NSX100B
- Device application: Distribution
- Poles description: 3P
- Protected poles description: 2t
- Network type: AC
- Network frequency: 50/60 Hz
- [In] Rated current: 100 A ( 40 °C )
- [Ui] Rated insulation voltage: 800 V AC 50/60 Hz
- [Uimp] Rated impulse withstand voltage : 8 kV
- [Ue] Rated operational voltage: 690 V AC 50/60 Hz
- Breaking capacity code: B (25 kA) AC
- Breaking capacity:
25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
15 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 - [Ics] Rated service breaking capacity:
Ics 20 kA 440 V AC 50/60 Hz conforming to IEC 60947-2
Ics 25 kA 380/415 V AC 50/60 Hz conforming to IEC 60947-2
Ics 40 kA 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Ics 7.5 kA 500 V AC 50/60 Hz conforming to IEC 60947-2 - Suitability for isolation:
Yes conforming to EN 60947-2
Yes conforming to IEC 60947-2 - Utilisation category: Category A
- Trip unit name: TM-D
- Trip unit technology: Thermal-magnetic
- Trip unit protection functions: LI
- Trip unit rating: 80 A ( 40 °C )
- Protection type:
Overload protection (thermal) L
Short-circuit protection (magnetic) I
Pollution degree: 3 conforming to IEC 60664-1
Complementary
- Control type: Toggle
- Mounting mode: Fixed
- Mounting support: Backplate
- Upside connection: Front
- Downside connection: Front
- Mechanical durability: 50000 cycles
- Electrical durability:
10000 cycles 690 V In conforming to IEC 60947-2
20000 cycles 690 V In/2 conforming to IEC 60947-2
30000 cycles 440 V In conforming to IEC 60947-2
50000 cycles 440 V In/2 conforming to IEC 60947-2 - Connection pitch: 35 mm
- Local signalling: Positive contact indication
- Long time pick-up adjustment type Ir: Adjustable
- Long time pick-up adjustment range: 0.7…1 x In
- Long time delay adjustment type: Fixed
- [tr] Long-time delay adjustment range:
15 s 6 x Ir
120…400 s 1.5 x In - Short-time pick-up adjustment type Isd: Fixed
- [Isd] Short-time pick-up adjustment range: 640 A
- Short-time delay adjustment type: Fixed
Environment
- Overvoltage category: Class II
- Electrical shock protection class: Class II
- Standards: EN/IEC 60947
- Product certifications:
Marine
CCC
EAC - IP degree of protection: IP40 conforming to IEC 60529
- IK degree of protection: IK07 conforming to IEC 62262
- Ambient air temperature for operation: -35…70 °C
- Ambient air temperature for storage: -55…85 °C
Ulasan
Belum ada ulasan.